Ccf Configuration Electrical Switchgear for Reliable Power Management

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
  • Ccf Configuration Electrical Switchgear for Reliable Power Management
Find Similar Products

Basic Info.

Model NO.
PN-XGN12/24
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Ccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

12kV XGN15 - 12 CCF Configuration Ring Main Unit: Uniquely Tailored for Advanced Power Management Solutions

The versatile XGN15 - 12 comes in an array of configurations that include DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV,and more. This narrative will concentrate on the CCF configuration. Each of these meticulously engineered configurations caters to distinct demands within power distribution systems, featuring various combinations of load break switch units, fuse-load break switch combination units, voltage transformer units, among other critical elements. The 12kV XGN15 - 12 CCF configuration ring main unit represents a cutting-edge electrical distribution solution, offering a remarkable fusion of regular load switching and heightened protection capabilities. This configuration is meticulously crafted to fulfill the specific requisites of power systems that necessitate a harmony of standard load control with pinpoint fault protection.

1. Ingenious Design and Component Functionality

Load Break Switch Units (C)

The two indispensable "C" units in the CCF configuration are pivotal for routine load current switching. These load break switches, imbued with high-caliber materials, assure steadfast performance. The use of silver-nickel alloys in the contacts bestows them with superior electrical conductivity and resilience. Capable of managing substantial load currents, each "C" unit supports the rated current of the ring main unit, generally spanning 630A to 1250A, contingent on the model.
 
These adept switches administer the power distribution to various electrical circuits or loads. For instance, in a medium-sized industrial plant, one "C" unit might energize production line machinery, while the other caters to the facility's lighting needs. Such load segregation permits autonomous control, facilitating operators to tailor the power output in alignment with the precise demand of each circuit.

Fuse - Load Break Switch Combination Unit (F)

The indispensable "F" unit in the CCF configuration merges the functionalities of a load break switch and a fuse. It is engineered to shield distinct sectors of the electrical system against over-currents and short-circuits. The fuse embedded within the "F" unit operates swiftly to disrupt the circuitry upon detecting unusual current levels.
 
Serving a dual purpose, the load break switch facet of the "F" unit also facilitates regular load current switching, enabling the connection or disconnection of electrical loads during standard operations, akin to a conventional load break switch. This dual functionality renders the "F" unit perfect for safeguarding vital apparatus, like transformers or high-value industrial machinery. For example, in a data center, it can protect the power supply of servers, ensuring electrical anomalies are swiftly isolated, thereby preserving the servers from potential harm.

2. Unyielding Construction

Enclosure

The CCF configuration ring main unit is encased within a robust and defensive housing. Typically fabricated from corrosion-resistant materials like galvanized steel or aluminum-coated steel, the enclosure is designed to conform to specific IP (Ingress Protection) ratings, generally between IP3X and IP5X. An IP3X rating safeguards against solid objects larger than 2.5 mm, whereas IP5X endows additional dust ingress protection.
 
The enclosure is also equipped with optimal ventilation to avert overheating during prolonged operation, complemented by a modular design that streamlines access to internal components for maintenance and repair. This modularity empowers technicians to effortlessly swap defective components, thus curtailing downtime and maintenance expenditures.

Mounting Structure

The unit boasts a robust and stable mounting structure, meticulously designed for secure installation. It offers versatile mounting options on walls, poles, or within switchgear cabinets. Engineered to resist vibrations and mechanical stress, this mounting structure ensures that the ring main unit remains steadfast during operation. Such stability is indispensable for the optimal performance of the load break switches and the fuse - load break switch combination unit, as any movement or misalignment could compromise their electrical efficacy.

3. Electrical Performance

Rated Voltage and Current

Sporting a rated voltage of 12kV, the XGN15 - 12 CCF configuration is ideally tailored for medium-voltage power distribution systems. It confidently manages the normal electrical load within its rated current capacity, guaranteeing a stable power supply during regular operating conditions. Its capacity to accommodate varying load currents makes it exceptionally adaptable to diverse electrical loads, ranging from small-scale commercial equipment to medium-sized industrial machinery.

Protection and Switching Efficiency

The ingenious integration of two load break switches and the fuse - load break switch in the CCF configuration delivers exceptional protection and switching efficiency. The fuse in the "F" unit acts swiftly in response to over-current and short-circuit faults, interrupting the current within milliseconds. The load break switches are adept at managing normal load currents effortlessly, and their design promises an extended operational lifespan, securing reliable power distribution over the years.

4. Versatile Applications

Industrial Settings

In industrial environments, the CCF configuration enhances power distribution management with precision. For instance, in a chemical manufacturing plant, the two "C" units can energize distinct production processes, while the "F" unit safeguards the vital pumps and compressors crucial for manufacturing. This configuration provides superior control over power distribution and significantly mitigates the risk of equipment damage due to electrical faults.

Commercial Buildings

For bustling commercial infrastructures like hotels or expansive retail outlets, the CCF configuration is a stellar solution for power management. The "C" units adeptly regulate the power supply across different building sections, such as lobbies, guest rooms, or store aisles. Meanwhile, the "F" unit is pivotal for protecting the building's core electrical components, like elevator control systems or central air-conditioning units, assuring their uninterrupted and safe functionality.
 
The 12kV XGN15 - 12 CCF configuration ring main unit emerges as a dependable and efficient solution for power distribution across varied applications. Its unique component synergy renders it an invaluable asset for systems demanding both routine load management and heightened fault protection.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Ccf Configuration Electrical Switchgear for Reliable Power ManagementCcf Configuration Electrical Switchgear for Reliable Power ManagementCcf Configuration Electrical Switchgear for Reliable Power ManagementCcf Configuration Electrical Switchgear for Reliable Power ManagementCcf Configuration Electrical Switchgear for Reliable Power Management

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now