Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
  • Ccf Configuration Electrical Switchgear for Optimal Power Distribution Systems
Find Similar Products

Basic Info.

Model NO.
PN-XGN12/24
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Ccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

12kV XGN15 - 12 CCF Configuration Ring Main Unit: Tailored for Selective Power Management

The XGN15 - 12 is available in various configurations such as DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV, among others. In this description, we will focus on the CCF configuration. However, each of these configurations is meticulously crafted to cater to diverse demands in power distribution systems, with flexible combinations of load break switch units, fuse-load break switch combination units, voltage transformer units, and other essential components. The 12kV XGN15 - 12 CCF configuration ring main unit is a premier electrical distribution solution, expertly blending routine load switching with superior protection capabilities. This specialized configuration is crafted to address the distinct needs of power systems, where a synergy of standard load regulation and pinpoint fault protection is crucial.

1. Design and Component Functionality

Load Break Switch Units (C)

The dual 'C' units in the CCF configuration are integral for managing routine load current switching. Constructed from top-grade materials, these load break switches guarantee steadfast performance. Featuring contacts crafted from silver-nickel alloys, they ensure remarkable electrical conductivity and durability. Capable of managing substantial load currents, each 'C' unit supports the ring main unit's rated current, typically ranging from 630A to 1250A, contingent on the model.
 
These sophisticated switches control power flow across various electrical circuits or loads. In scenarios such as medium-scale industrial settings, one 'C' unit could power production line machinery, while the other 'C' unit illuminates the facility. This load segregation permits autonomous control, empowering operators to fine-tune power supply congruent with actual circuit demands.

Fuse-Load Break Switch Combination Unit (F)

The 'F' unit within the CCF configuration stands as a pivotal component, merging the roles of a load break switch and a fuse. This unit is engineered to shield specific sections of the electrical system from over-currents and short-circuits. The fuse in the 'F' unit, a swift-acting device, promptly disrupts the circuit upon abnormal current detection.
 
Acting also as a load break switch, the 'F' unit accommodates regular load current switching, enabling connection or disconnection of loads during normal operations. This dual capability renders the 'F' unit indispensable for safeguarding critical equipment, such as transformers or high-value industrial machinery. For example, within a data center, the 'F' unit secures the servers' power supply, ensuring rapid electrical fault isolation and protecting servers from potential damage.

2. Robust Construction

Enclosure

The CCF configuration ring main unit is housed within a robust, protective casing. Typically crafted from corrosion-resistant materials like galvanized or aluminum-coated steel, the enclosure meets specific IP (Ingress Protection) standards, generally ranging from IP3X to IP5X. An IP3X rating guards against solid objects over 2.5 mm, while IP5X offers added protection against dust intrusion.
 
The enclosure is thoughtfully designed with adequate ventilation to avert overheating during continuous use. Its modular construction not only facilitates easy access to internal components but also streamlines maintenance and repairs. This modularity allows technicians to efficiently replace defective parts, minimizing downtime and maintenance expenses.

Mounting Structure

The unit is a marvel of engineering, equipped with a robust mounting structure designed to guarantee secure installation. Whether mounted on walls, poles, or nestled within switchgear cabinets, it stands unyielding. Crafted to endure vibrations and mechanical stresses, the ring main unit remains steadfast, ensuring flawless operation. This unwavering stability is vital for the optimal performance of load break switches and the fuse-load break switch combination unit, as any shift or misalignment could impact their electrical efficiency.

3. Electrical Performance

Rated Voltage and Current

Boasting a rated voltage of 12kV, the XGN15-12 CCF configuration is ideally tailored for medium-voltage power distribution systems. It gracefully manages the regular electrical load within its rated current capacity, ensuring consistent power supply under normal conditions. Its versatility in handling varied load currents makes it adaptable to a wide range of electrical demands, from small-scale commercial devices to medium-sized industrial machinery.

Protection and Switching Efficiency

The ingenious fusion of two load break switches and the fuse-load break switch in the CCF configuration delivers remarkable protection and switching efficiency. The fuse in the 'F' unit is engineered for rapid response to over-current and short-circuit anomalies, severing the current within milliseconds. The load break switches manage normal load currents effortlessly, with a design that promises long-lasting operational life, ensuring dependable power distribution over time.

4. Versatile Applications

Industrial Settings

In bustling industrial plants, the CCF configuration excels in managing power distribution with precision. Consider a chemical manufacturing plant, where the two 'C' units can energize distinct production processes, while the 'F' unit vigilantly shields essential pumps and compressors crucial for manufacturing. This configuration facilitates superior control of power distribution, significantly mitigating the risk of equipment damage from electrical faults.

Commercial Buildings

In commercial edifices like hotels or expansive retail complexes, the CCF configuration stands out as a superior power management solution. The 'C' units adeptly control power supply to varied building areas, such as the lobby, guest rooms, or store aisles. Meanwhile, the 'F' unit safeguards vital electrical systems, including elevator controls and central air-conditioning units, ensuring their continuous, safe operation.
 
The 12kV XGN15-12 CCF configuration ring main unit is a paragon of reliability and efficiency in power distribution, adaptable to diverse applications. Its innovative component synergy positions it as an invaluable choice for systems demanding both routine load management and advanced fault protection.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Ccf Configuration Electrical Switchgear for Optimal Power Distribution SystemsCcf Configuration Electrical Switchgear for Optimal Power Distribution SystemsCcf Configuration Electrical Switchgear for Optimal Power Distribution SystemsCcf Configuration Electrical Switchgear for Optimal Power Distribution SystemsCcf Configuration Electrical Switchgear for Optimal Power Distribution Systems