Tailored Distribution Box Solutions with Rmu Ring Main Units Design

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
  • Tailored Distribution Box Solutions with Rmu Ring Main Units Design
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
Pino
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Cccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

Product Description

The RMU is available in a dazzling array of configurations such as DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV, among others. In this elaborate presentation, we will delve into the CCCF configuration. Every configuration is meticulously crafted to fulfill distinct requirements in power distribution systems. They feature diverse combinations of load break switch units, fuse-load break switch combination units, voltage transformer units, and assorted components, ensuring tailored solutions for any power distribution need. The RMU configuration ring main unit stands as a pinnacle of sophistication in electrical distribution devices, merging the functions of multiple load break switches and a fuse-load break switch. This configuration is finely tailored to address the multifaceted power management demands of contemporary electrical systems, offering an exceptional balance between load control and fault protection.

1. Design and Component Functionality

Load Break Switch Units (C)

The trio of 'C' units in the CCCF configuration are high-performance load break switches, the stalwarts of the ring main unit for handling normal load currents. Constructed with robust materials and often featuring contacts crafted from advanced alloys like silver-tungsten, this combination ensures low electrical resistance, minimizing power losses. Their excellent wear resistance enables them to withstand countless switching operations throughout their lifespan.
 
Each load break switch operates independently, offering unparalleled flexibility in power distribution. In expansive industrial facilities, one 'C' unit could power production machinery, another auxiliary equipment like conveyor belts and pumps, and the third the lighting systems. This strategic separation allows for precise power supply control, enabling operators to manage energy consumption adeptly and isolate any issues within specific circuits.

Fuse - Load Break Switch Combination Unit (F)

The 'F' unit in the CCCF configuration is an indispensable component, seamlessly integrating the functions of a load break switch and a fuse. It's dedicated to protecting the electrical system from over-current and short-circuit conditions. The fuse within the 'F' unit is a rapid-response device, detecting abnormal current levels and promptly interrupting the circuit, thereby safeguarding downstream equipment from potential harm.
 
The load break switch part of the 'F' unit also permits normal load current switching, enabling connection or disconnection of electrical loads during regular operation. This dual functionality makes the 'F' unit ideal for protecting crucial equipment, such as transformers or high-value industrial machinery. For instance, in a power distribution network, the 'F' unit can safeguard a distribution transformer from over-currents, ensuring its safe and reliable operation.

2. Robust Construction

Enclosure

The CCCF configuration ring main unit is encased in a robust and protective enclosure, typically forged from high-grade steel. This offers spectacular protection against mechanical impacts, dust, and moisture, meeting rigorous IP (Ingress Protection) standards, commonly ranging from IP3X to IP6X. An IP3X rating shields against solid objects larger than 2.5 mm, whereas an IP6X rating offers complete protection against dust ingress.
 
The enclosure is ingeniously designed with proper ventilation to dissipate heat generated during operation, safeguarding the stability of internal components. Its modular design simplifies access for maintenance and repair, allowing technicians to swiftly replace faulty parts, thus minimizing downtime and maintenance expenditures.

Mounting Structure

The unit is fortified with a steadfast mounting structure for secure installation. It offers versatile mounting options on walls, poles, or within switchgear cabinets. The mounting structure is meticulously engineered to withstand vibrations and mechanical stress, ensuring the ring main unit remains securely in place during operation. This steadfast stability is vital for the optimal function of load break switches and the fuse-load break switch combination unit, as any movement or misalignment could compromise their electrical performance.

3. Electrical Performance

Rated Voltage and Current

Engineered with a proficient rated voltage of 12kV, our RMU configuration stands as an exemplary fit for medium-voltage power distribution architectures. It boasts an adaptable current range, accommodating rated currents spanning from 630A to an impressive 2000A, contingent upon the selected model. This robust capability makes it an ideal choice for energizing diverse electrical loads, whether in small-scale operations or extensive industrial machinery and commercial infrastructure systems.

Protection and Switching Efficiency

Our innovative CCCF configuration, integrating three adept load break switches alongside a fuse-load break switch, delivers extensive electrical protection coupled with efficient switching prowess. The fuse within the 'F' unit offers rapid response to over-current and short-circuit anomalies, severing the current in mere milliseconds. Designed for longevity, the load break switches seamlessly manage normal load currents, assuring sustained, dependable power distribution over time.

4. Versatile Applications

Industrial Settings

Within industrial environments, the CCCF configuration optimizes power distribution with precision. Envision an automotive manufacturing hub: the trio of 'C' units can energize distinct production sectors, such as body-in-white assembly, paint applications, and final assembly processes. Meanwhile, the 'F' unit safeguards vital robotic machinery integral to manufacturing. This strategic configuration enhances power management and mitigates the risk of electrical disruptions.

Commercial Buildings

In expansive commercial edifices like vast shopping complexes or towering office blocks, the CCCF configuration offers a sophisticated power management solution. The 'C' units adeptly regulate power across distinct building sections, such as retail zones, office suites, and parking facilities. Concurrently, the 'F' unit provides critical protection for essential building systems-such as elevator controls and central air-conditioning units-ensuring their seamless, secure operation.
 
Our RMU configuration, embodying the ring main unit, emerges as a pinnacle of reliability and efficiency for power distribution across various applications. Its distinctive amalgamation of components renders it an indispensable choice for systems necessitating proficient load management alongside advanced fault protection.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Tailored Distribution Box Solutions with Rmu Ring Main Units DesignTailored Distribution Box Solutions with Rmu Ring Main Units DesignTailored Distribution Box Solutions with Rmu Ring Main Units DesignTailored Distribution Box Solutions with Rmu Ring Main Units DesignTailored Distribution Box Solutions with Rmu Ring Main Units Design