Low Voltage Switchgear with Ccf Configuration for Power Distribution

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
  • Low Voltage Switchgear with Ccf Configuration for Power Distribution
Find Similar Products

Basic Info.

Model NO.
PN-XGN12/24
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Ccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

12kV XGN15 - 12 CCF Configuration Ring Main Unit: A Power Management Marvel with Precision Tailoring for Selective Power Management.

The XGN15 - 12 offers a versatile array of configurations tailored to meet diverse power distribution needs, including DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV,and many more. This feature-rich description will delve into the CCF configuration. Each of these configurations is crafted to address specific power distribution system requirements, incorporating a variety of components such as load break switch units, fuse-load break switch combinations, voltage transformer units, and other essential elements. The 12kV XGN15 - 12 CCF configuration ring main unit stands as an exemplary electrical distribution solution, merging normal load switching with superior protection capabilities. Designed for systems necessitating a seamless blend of standard load control and dedicated fault protection, it delivers unmatched efficacy.

1. Design and Component Functionality

Load Break Switch Units (C)

The dual "C" units in the CCF configuration are pivotal for regular load current switching. Crafted from premium materials, these switches ensure reliability, with contacts made of silver-nickel alloys for optimal conductivity and minimal wear. Each "C" unit adeptly manages sizable load currents, typically ranging from 630A to 1250A, depending on the specific model of the ring main unit.
 
These switches masterfully direct power to various circuits or loads. In a mid-sized industrial setting, one "C" unit might energize production line machinery, while the other powers the facility's lighting system, thereby allowing for independent control and strategic power supply adjustments to meet circuit demands.

Fuse - Load Break Switch Combination Unit (F)

The "F" unit in the CCF setup is indispensable, merging load break switch functions with fuse protection. It safeguards vital electrical system portions from over-currents and short-circuits. The fast-acting fuse in the "F" unit swiftly disrupts the circuit upon detecting abnormal current flows.
 
Beyond protection, the load break switch in the "F" unit facilitates standard current switching, allowing seamless load connectivity and disconnection. This dual-purpose feature makes the "F" unit ideal for safeguarding critical assets like transformers or high-value industrial machinery. In data centers, it can protect server power supplies, quickly isolating faults to prevent server damage.

2. Robust Construction

Enclosure

The CCF configuration ring main unit is housed in a robust, corrosion-resistant casing, typically of galvanized or aluminum-coated steel. Complying with IP standards, usually between IP3X and IP5X, the enclosure is designed to fend off solid objects and dust, ensuring longevity and reliability.
 
Featuring strategic ventilation, the enclosure averts overheating during continuous use. Its modular design facilitates easy access for maintenance, allowing effortless replacement of components, which significantly minimizes downtime and maintenance expenses.

Mounting Structure

Our state-of-the-art unit is ingeniously designed with a robust and stable mounting structure, ensuring a seamless and secure installation experience. Whether mounted on walls, poles, or neatly integrated within switchgear cabinets, this mounting foundation is meticulously engineered to withstand vibrations and mechanical stress, guaranteeing that the ring main unit steadfastly remains in place during operation. This impeccable stability is crucial to the flawless performance of the load break switches and the ingenious fuse-load break switch combination unit, as even the slightest movement or misalignment could compromise their exceptional electrical performance.

3. Electrical Performance

Rated Voltage and Current

The XGN15 - 12 CCF configuration, with its impressive rated voltage of 12kV, is masterfully crafted for medium-voltage power distribution systems. With the capability to manage normal electrical loads within its rated current capacity, it ensures a stable and reliable power supply under normal operating conditions. Thanks to its versatile design, it adeptly handles varying electrical loads, making it ideal for applications ranging from small-scale commercial equipment to medium-sized industrial machinery.

Protection and Switching Efficiency

Boasting a superior level of protection and switching efficiency, the innovative combination of two load break switches and the fuse-load break switch in the CCF configuration is unparalleled. The fuse in the 'F' unit is engineered to swiftly respond to over-current and short-circuit faults, cutting off the current in mere milliseconds. Meanwhile, the load break switches are designed to effortlessly handle normal load currents, ensuring a prolonged operational life and delivering unwavering power distribution reliability over time.

4. Versatile Applications

Industrial Settings

In the realm of industrial plants, the CCF configuration stands as a beacon of precision in power distribution management. Take, for example, a chemical manufacturing plant: the two 'C' units can adeptly supply power to different production processes, while the 'F' unit ensures the protection of critical pumps and compressors vital for manufacturing. This configuration not only enhances control over power distribution but also significantly mitigates the risk of equipment damage due to electrical faults, safeguarding the plant's operations.

Commercial Buildings

In the dynamic environment of commercial buildings, such as hotels or expansive retail stores, the CCF configuration emerges as the quintessential solution for effective power management. The 'C' units can efficiently manage the power supply to distinct areas within the building-be it the lobby, guest rooms, or store aisles. Simultaneously, the 'F' unit plays a crucial role in protecting the building's main electrical apparatus, like elevator control systems or central air-conditioning units, ensuring their continuous, uninterrupted, and safe operation.
 
The 12kV XGN15 - 12 CCF configuration ring main unit stands as a paragon of reliability and efficiency in power distribution across diverse applications. Its exceptional combination of components makes it an invaluable choice for systems requiring seamless load management and superior fault protection.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Low Voltage Switchgear with Ccf Configuration for Power DistributionLow Voltage Switchgear with Ccf Configuration for Power DistributionLow Voltage Switchgear with Ccf Configuration for Power DistributionLow Voltage Switchgear with Ccf Configuration for Power DistributionLow Voltage Switchgear with Ccf Configuration for Power Distribution