Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
  • Efficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems
Find Similar Products

Basic Info.

Model NO.
Pino
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Cccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

 

The RMU, optimized for a diverse array of configurations, is crafted to seamlessly integrate into your power distribution system with options such as: DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV,among others. In this enriching overview, we will delve into the intricacies of the CCCF configuration, a standout model. However, each configuration is engineered for distinct roles within the power distribution landscape, featuring unique blends of load break switch units, fuse-load break switch combinations, voltage transformers, and an array of specialized components. The RMU configuration ring main unit emerges as a pinnacle of electrical distribution technology. It synergizes multiple load break switches with a fuse-load break switch to accommodate the sophisticated power management needs of contemporary electrical networks, ensuring a harmonious balance between precise load control and robust fault protection.

1. Design and Component Functionality

Load Break Switch Units (C)

The trio of 'C' units in the CCCF configuration are high-performance load break switches, pivotal for normal load current management. Crafted from resilient materials, these switches often feature contacts composed of advanced silver-tungsten alloys. Such a combination ensures minimal electrical resistance during conduction, resulting in reduced power losses and exceptional wear resistance, empowering them to endure countless switching cycles over their extended lifespan.
 
Each load break switch is conceived to function autonomously, providing unparalleled flexibility in power distribution. In an expansive industrial plant, one 'C' unit might be tasked with energizing the production machinery, another with auxiliary systems like conveyor belts and pumps, while the third serves the lighting network. This strategic separation of loads paves the way for meticulous control over the power supply, allowing operators to optimize energy usage and swiftly isolate any discrepancies in specific circuits.

Fuse-Load Break Switch Combination Unit (F)

The 'F' unit in the CCCF configuration stands as a linchpin, amalgamating load break switch functionalities with a fuse. This unit is pivotal for safeguarding the electrical setup against over-current and short-circuit incidents. The fuse element within the 'F' unit acts with swiftness, detecting abnormal current surges and promptly disconnecting the circuit to shield downstream equipment from potential detriment.
 
The load break switch component of the 'F' unit also facilitates normal load current operations, enabling seamless load connectivity or disconnection during routine processes. This dual capability renders the 'F' unit ideal for protecting vital infrastructure, such as transformers or high-value industrial apparatus. For instance, in a power distribution schema, the 'F' unit diligently protects a distribution transformer from over-currents, ensuring its steadfast and secure functionality.

2. Robust Construction

Enclosure

The CCCF configuration ring main unit is encased in a resilient, protective enclosure. Constructed from premium-grade steel, it delivers formidable defense against mechanical impacts, dust, and moisture intrusion. It is engineered to conform to stringent IP (Ingress Protection) standards, typically ranging from IP3X to IP6X. An IP3X grade protects against solid intrusions exceeding 2.5 mm, while an IP6X rating ensures complete dust impermeability.
 
The enclosure is also equipped with efficient ventilation to dissipate operational heat, maintaining the integrity of internal components. Moreover, its modular design simplifies maintenance access, allowing technicians to efficiently replace defective components, thereby minimizing downtime and reducing maintenance expenditures.

Mounting Structure

The unit incorporates a robust mounting structure for secure installation on walls, poles, or within switchgear cabinets. This structure is meticulously engineered to endure vibrations and mechanical stresses, assuring that the ring main unit remains steadfastly in place during operation. This stability is vital for the optimal performance of load break switches and the fuse-load break switch unit, as any movement or misalignment could compromise their electrical efficacy.

3. Electrical Performance

Rated Voltage and Current

Our Efficient Outdoor Switch Equipment for RMU Ring Main Unit Systems, with a remarkable rated voltage of 12kV, is masterfully designed for seamless integration within medium-voltage power distribution frameworks. It expertly accommodates a diverse spectrum of rated currents, ranging from 630A to an impressive 2000A, contingent on the chosen model. This exceptional capacity empowers it to efficiently energize a vast array of electrical loads, from modest to grand-scale industrial machinery, as well as sophisticated commercial infrastructures.

Protection and Switching Efficiency

The CCCF configuration within our premier RMU solution harmoniously integrates three load break switches alongside a fuse-load break switch, crafting an unparalleled shield of electrical protection coupled with superior switching efficiency. The high-performance fuse in the 'F' unit responds with lightning speed to over-current and short-circuit anomalies, severing currents within mere milliseconds. The load break switches are engineered to adeptly manage normal load currents with outstanding smoothness, their robust design extending their operational longevity, thus ensuring steadfast power distribution reliability for years to come.

4. Versatile Applications

Industrial Settings

In dynamic industrial environments, our CCCF configuration proves indispensable for refined power distribution management. Taking an automotive manufacturing plant as an illustrative example, the three 'C' units channel power to distinct production zones such as body-in-white assembly, paint shops, and final assembly lines, while the 'F' unit provides vital protection to pivotal robotic machinery, mitigating the risk of electrical damage. This strategic configuration enhances power distribution control while significantly diminishing the likelihood of equipment impairment due to electrical anomalies.

Commercial Buildings

In expansive commercial edifices, such as vast shopping complexes or towering office skyscrapers, our CCCF configuration emerges as a quintessential power management solution. The 'C' units adeptly regulate power distribution across various building zones, including retail sectors, office levels, and parking spaces. Meanwhile, the 'F' unit vigilantly safeguards crucial infrastructure, such as elevator control mechanisms and central air-conditioning systems, ensuring their uninterrupted and secure functionality. This comprehensive system elevates the operational safety and efficiency of the building's core electrical components.
 
The RMU configuration ring main unit is celebrated for its unmatched reliability and efficiency in diverse power distribution scenarios. Its artful amalgamation of components positions it as an invaluable selection for systems requiring both proficient load management and superior fault protection.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Efficient Outdoor Switch Equipment for Rmu Ring Main Unit SystemsEfficient Outdoor Switch Equipment for Rmu Ring Main Unit SystemsEfficient Outdoor Switch Equipment for Rmu Ring Main Unit SystemsEfficient Outdoor Switch Equipment for Rmu Ring Main Unit SystemsEfficient Outdoor Switch Equipment for Rmu Ring Main Unit Systems