Custom Configuration Medium Voltage Switchgear for Reliable Power Supply

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

National Award received
This supplier had received national award, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (24)
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
  • Custom Configuration Medium Voltage Switchgear for Reliable Power Supply
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
Pino
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Province
Jiangxi
Color
Custom
Configuration
Cccf
Rated Voltage
Rated Voltage
Protection Class
IP65
Rated Frequency
50Hz/60Hz
Transport Package
Wooden Packing
Specification
Custom
Trademark
Pino Electric
Origin
China
HS Code
85381010
Production Capacity
2000

Product Description

Product Description

 

The RMU, a marvel of engineering, is available in a dazzling array of configurations, including DF, CC, CCC, CCCC, FCC, CCF, CCCF, CCCCF, CF, CFC, CCFF, CCCFF, CFFC, CCVV, among others. In this extensive exploration, we will delve into the CCCF configuration. Nonetheless, each of these meticulously crafted configurations is uniquely designed to cater to diverse power distribution system requirements, showcasing variations in the synergy of load break switch units, fuse - load break switch combination units, voltage transformer units, and a host of other components. The RMU configuration ring main unit is an epitome of sophisticated electrical distribution design, flawlessly integrating the functions of multiple load break switches with a fuse - load break switch. This configuration is ingeniously tailored to meet the intricate power management demands of modern electrical systems, providing a harmonious blend of load control and fault protection with unparalleled efficiency.

1. Ingenious Design and Component Functionality

High-Performance Load Break Switch Units (C)

The formidable trio of "C" units in the CCCF configuration are high - performance load break switches, the true powerhouses within the ring main unit, adept at handling normal load currents with finesse. Crafted from robust materials, these switches often boast contacts composed of advanced silver - tungsten alloys, ensuring minimal electrical resistance and power losses, while showcasing exceptional wear resistance to endure countless switching operations over their impressive lifespan.
 
Individually designed for autonomous operation, each load break switch provides unmatched flexibility in power distribution. In expansive industrial facilities, one "C" unit might be harnessed to energize production machinery, another dedicated to auxiliary equipment like conveyor belts and pumps, and a third assigned to lighting systems. This strategic separation of loads allows for precise control over power supply, enabling operators to effectively manage energy consumption and swiftly isolate any circuit issues that may arise.

Fusing Innovation: Fuse - Load Break Switch Combination Unit (F)

The pivotal "F" unit within the CCCF configuration seamlessly integrates the dual functions of a load break switch and a fuse. This vital component is engineered to shield the electrical system from over - current and short - circuit incidents. The fast - acting fuse within the "F" unit is a vigilant guardian, detecting abnormal current levels and promptly interrupting the circuit, thereby protecting downstream equipment from potential harm.
 
Simultaneously, the load break switch segment of the "F" unit facilitates routine load current switching, akin to its counterparts. This dual - functionality renders the "F" unit indispensable for safeguarding critical equipment, such as transformers or invaluable industrial machinery. For instance, in a power distribution network, the "F" unit can safeguard a distribution transformer against over - currents, ensuring its steady and reliable operation.

2. Unyielding Robust Construction

Durable Enclosure

The CCCF configuration ring main unit is ensconced within a durable and robust enclosure, typically forged from high - grade steel that offers formidable defense against mechanical impacts, dust, and moisture intrusion. It is meticulously designed to conform to stringent IP (Ingress Protection) standards, frequently within the IP3X - IP6X range. An IP3X rating guards against solid objects exceeding 2.5 mm, while an IP6X rating affords comprehensive dust ingress protection.
 
Additionally, the enclosure is equipped with efficient ventilation to effectively dissipate heat generated during operation, thereby preserving the stability and longevity of internal components. Its modular design facilitates effortless access for maintenance and repair, empowering technicians to swiftly replace faulty parts, significantly minimizing downtime and curbing maintenance costs.

Sturdy Mounting Structure

The unit is fortified with a stable and reliable mounting structure, allowing for secure installation on walls, poles, or within switchgear cabinets. This expertly engineered structure is designed to withstand vibrations and mechanical stresses, ensuring the ring main unit remains securely anchored during operation. This unwavering stability is essential for the optimal functioning of load break switches and the fuse - load break switch combination unit, as any displacement or misalignment could compromise their electrical performance.

3. Electrical Performance

Rated Voltage and Current

Our Custom Configuration Medium Voltage Switchgear is engineered with precision, featuring an impressive rated voltage of 12kV. This robust configuration is adeptly tailored for medium-voltage power distribution systems and accommodates a diverse range of rated currents, spanning from 630A to an exceptional 2000A, contingent upon the specific model. This expansive current-handling capacity makes it a perfect fit for energizing a spectrum of electrical loads, from compact industrial apparatus to vast commercial building networks, ensuring seamless operations across all platforms.

Protection and Switching Efficiency

The innovative CCCF configuration stands out with its trio of load break switches, complemented by a fuse-load break switch, delivering unparalleled electrical protection coupled with superior switching prowess. The precision-engineered fuse within the 'F' unit acts with lightning speed in the event of over-current and short-circuit anomalies, effectively severing the current in mere milliseconds. Meanwhile, the load break switches adeptly manage standard load currents with ease. Their enduring design guarantees a prolonged operational lifespan, ensuring dependable power distribution through the years, firmly underpinning the safety and efficiency of your systems.

4. Versatile Applications

Industrial Settings

In dynamic industrial environments, the CCCF configuration offers a strategic edge in power distribution management. Take, for instance, a bustling automotive manufacturing plant: the trio of 'C' units can be strategically deployed to energize distinct production realms, such as the body-in-white assembly, paint shop, and final assembly lines. Simultaneously, the 'F' unit serves a critical role in safeguarding pivotal robotic equipment against potential electrical mishaps. This configuration not only enhances control over power distribution but also significantly mitigates the risk of damage, ensuring smooth, uninterrupted industrial operations.

Commercial Buildings

In the realm of commercial architecture, from sprawling shopping malls to towering office skyscrapers, the CCCF configuration emerges as a champion of effective power management. The agile 'C' units are tasked with regulating the power supply across various building zones, including retail spaces, office floors, and parking facilities. Concurrently, the 'F' unit is dedicated to shielding the building's indispensable electrical infrastructure, such as elevator control mechanisms or central air-conditioning networks. This guarantees their relentless and secure operation, ensuring business continuity and tenant safety.
 
The RMU configuration ring main unit epitomizes reliability and efficiency in power distribution across multiple applications. Its sophisticated array of components positions it as an invaluable asset for systems demanding adept normal load management alongside heightened fault protection, making it an ideal choice for diverse scenarios.
 
Technical Specification PN-XGN12/24 Switchgear
Rated voltage kV 12 24
Frequency Hz 50/60 50/60
Lightning impulse withstand voltage Phase to phase, phase to earth kV 75 125
Fracture kV 85 145
1 min Power frequency withstand voltage Phase to phase, phase to earth kV 42 65
Fracture kV 48 79
Rated frequency Hz 50/60 50/60
Rated current Main bus A 630 630
Branch bus A 630 630
Short time withstand current Main circuit kA 20/3S 20/3S
Earthing circuit kA 20/2S 20/2S
Rated withstand current (peak) kA 50 50
Rated transfering current A 1700 870
Protection level Ip2x
Load break switch mechanical life Times 2000 3000
Earthing switch mechanical life Times 2000 2000
 
Custom Configuration Medium Voltage Switchgear for Reliable Power SupplyCustom Configuration Medium Voltage Switchgear for Reliable Power SupplyCustom Configuration Medium Voltage Switchgear for Reliable Power SupplyCustom Configuration Medium Voltage Switchgear for Reliable Power SupplyCustom Configuration Medium Voltage Switchgear for Reliable Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier